Tyco C1714 VDR Interface Board 509.023.071
The Tyco C1714 (509.023.071) Voyage Data Recorder Output Module provides outputs for connection to a ship’s Voyage Data Recorder to allow recording of various panel events. Volt-free relay contacts are provided along with a RS422 serial port which conforms to IEC 61162-1. The serial data output conforms to IEC PAS 61162-102 – Extra Requirements for the Voyage Data Recorder.
Connection to the panel motherboard is via a 10-way ribbon cable. This carries the power supply connections and the RS485 serial data comms. The panel must have a C1630 Output Expansion Interface Board fitted and set for VDR comms. It is fitted as standard to the T1216C and T1232C. The VDR is not supported on the T1204.
Five volt-free changeover contacts provide the following signals:
- Common Fire
- Machinery space fire detected (Any zone or number of zones can be configured to operate this output)
- Common Fault – Fail-Safe
- Mains Failed – Fail-Safe
- Back-up Supply Failed – Fail Safe
A 2-wire serial data output (RS422) is also provided, which conforms to IEC 61162-1. This provides zonal status information as well as the above signals.
Key features include:
- Provides outputs for connection to a ship’s Voyage Data Recorder to allow recording of various panel events
- Provides zonal status information
- Five volt-free changeover contacts
- Product Code: C1714 (509.023.071)
How to order (Specify Model): Select C1714 (509.023.071)
Part Number | Description |
509.023.071 |
C1714 T1200-C Serial VDR PCB |
Where To Buy | Global Sales and Support. Dedicated to advancing safety worldwide. Contact Us